VW-1 Flame Test for Cables Horizontal Sample FT2 Burning Test
UL1581 Single Cable and Wire Burning Test Machine
Cable and wire flame resistant machine meets requirements of
UL1581-2001, which section of 1060 (uprightness burning and FT1
test), 1061 (cable burning test), 1080 (VW-1 burning test), 1090
(burning test of electrical equipment' wire) and 1100 (The test
specimen oriented horizontally / FT2 burning test).
Equipment Composition
Test machine + control system + high accuracy extended burning
control system + temperature testing system + testing equipment and
testing fixture + burning air and flow control system
Testing Fixture Specifications
| Model | Cable and wire flame resistant chamber |
|---|
| Main Fixtures | Test stand and burning torch |
|---|
| Test Stand | Stainless steel S304. Vertical and horizontal stand |
|---|
| Burning Torch | ASTM D 5025-99 |
|---|
| Standard Power | Vertical torch: 500W Horizontal torch: 225W |
|---|
| Crater Diameter | 0.90±0.03mm |
|---|
| Crater Lamp Length | 1.60±0.05mm |
|---|
| Height from Torch to Air Entrance | 102mm |
|---|
| Torch Lamp Angle | Horizontal 90°, vertical 20° (Vertical axis remains on the vertical
plane and keeps 20 degree in vertical direction) |
|---|
Test Chamber Features
• Made from stainless steel with nice appearance and rust corrosion
resistance
• Ventilation and smoke-releasing system on top for exhaust gas
removal
• Steel glass door on front for observation during testing
• Operate panel on right side of observation door
• Chamber specification: 200X120X200(CM), volume: 4.8m³
Control System Options
Intelligent Touch Screen + PLC: Controls testing time, frequency and extended time with menu-type
operation and accurate results
Time Relay Control: Traditional relay control for testing time (0~999.9S), stop
burning time (0~99.9s), burning frequency (1~9999), and extended
time (0~999.9S)
Extended Control System
High accuracy extended burning control system (photographic control
system) automatically records stopping burning time, reducing
testing tolerances
Temperature Testing System
• Thermal sensor with copper pipe construction and thermocouple
• K-type thermocouple with 0.5mm diameter stainless steel pipe
coating
• Intelligent PID temperature list matched with K-type
thermocouple, indication over 1000℃
Burning Air and Flow Control
Burning Air: Methane (purity 98%, thermal number 998 BTU/cubic feet, 37.1 per
cubic meter mega joule)
Control System Includes: Flow meter and pressure reducing valves
Flow Meter: Calibrated by D3195 criterion with 2% accuracy, flow scale
1000ml/min
Pressure Reducing Valves: 1 EA, air flow shift to 10 pound/cube inch